Balancell Quick Chargers

Available for 26V 39V 52V batteries

Overload Protection

Over Voltage Protection

Short Circuit Protection

Over Temperature Protection

with auto recover

Charger Installation Requirements
Charger Model52V 160A, 52V 100A52V 60A, 26V 100A
Circuit Breakers3 phase, 20A / pole. Inrush current 55A.Single phase, 20A. Inrush current 55A.
Socket3P+ Neutral+ Earth. The charger will not function without the neutral. 32 A / pole
IEC 60309 – Red coding
Type M socket
3 pin, single phase, live + neutral + earth (The charger will not function without the neutral)
230V, 15A
Wiring5 core, 3P + N + E
30 A / phase
3 core, L+ N + E
20 A / phase
Operation Notes
1. Filters must regularly be:
  • Inspected
  • Cleaned
  • Replaced

2. Safe ambient temperature range is -25°C to 50°C

3. Front Panel LED indicators:

  • The GREEN OUTPUT OK light indicates that the charger voltage is within a normal operating range
  • The RED OVER TEMPERATURE light turns on and stays on if the charger has experienced an over temperature condition or if a fan has failed. The charger will stop charging until it returns to a safe operating temperature, at which point it will resume operation and the red light will turn off.

Charger Safety and EMC
StandardsUL62368-1, TUV EN62368-1, EAC TP TC 004 approved
Withstand VoltageI/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
IsolationI/P-O/P, I/P-FG, O/P-FG:100M ohms / 500VDC /25degC /70% RH
EMC EmissionParameterStandardTest Level / Notes
ConductedEN55032 (CISPR32) / EN55011 (CISPR11)Class B
RadiatedEN55032 (CISPR32) /
EN55011 (CISPR11)
Class A
Harmonic CurrentEN61000-3-2
Voltage FlickerEN61000-3-3
EMC ImmunityEN55024, EN61204-3, EN61000-6-2
ParameterStandardTest Level / Notes
ESDEN61000-4-2Level 3, 8kV air; Level 2,
4kV contact
RadiatedEN61000-4-3Level 3
EFT / BurstEN61000-4-4Level 3
SurgeEN61000-6-22kV/Line-Line 4kV / Line-Earth
ConductedEN61000-4-6Level 3
Magnetic FieldEN61000-4-8Level 4
Voltage Dips and InterruptionsEN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods >95% interruptions 250 periods